LSP 3000

Product Details: LSP AutoVent 3000


Features:
  • Bright Green Visual Breath Indicator
  • Built-in Audible Pressure Limit Alarm
  • Intermittent Mandatory Ventilation
  • Indicator for Verification of Gas Delivery
  • Gas Powered, No Batteries Required
  • Meets AHA, ASTM and KKK-1822C Standards
  • Easy Cleaning and Sterilization
  • Independent Control over Rate and Volume
The LSP AutoVent 3000 is a portable, compact emergency transport ventilator with a variety of applications from industrial and volunteer EMS use to air and ground transport. Offering controlled ventilation at rates of 8-28 breaths per minute as well as additional inspiratory time settings, the AutoVent meets most critical emergency care situations and in-hospital transports.

The AutoVent 3000 comes with the LSP patient valve and supply tubing, the control module, six feet of oxygen hose, a non-rebreathing valve (to attach Peep), and connecting tubing. The attached patient valve allows a patient to draw supplemental gas flow (up to 48 LPM) with a spontaneous effort. The AutoVent is available as an anti-inhalation valve for use in toxic environments. The ventilator operates exclusively on source gas with no air entrainment, so specified concentrations of oxygen can be easily maintained.

Specifications


Control Module:
  • Supply Pressure Range: 40 to 90 psig
  • Storage Temperature: -40°F to 160°F
  • Frequency: 8 to 28 BPM
  • Tidal Volume: 400 to 1200 ml.
  • Flow Rate: 16 to 48 LPM
  • Inspiratory Time: 1.5 to 2 seconds
  • Expiratory Time: 1.5 to 6.0 seconds
  • I:E Ratio: 1:1 to 1:4
  • Dead Space in Patient Valve Assembly: 8 ml
  • Weight: 24 oz./680g.
  • Expiratory Resistance: 5 cm. H20
  • Minute Volume: 0 to 24 LPM
  • Case Material: ABS
  • Input Connection: Plated brass
  • Output Connectors: Plated brass 
  • Gas Consumption Driving Gas: 0.5 LPM Maximum
Patient Valve Assembly:
  • Flow: As required in demand valve mode: 0-48 LPM at 50 psig. Depends on volume setting.
  • Peak Inspiratory Flow: 48 LPM at airway pressure drop of less than 2.5 cm H20
  • Delivery Pressure: 60 ±5 cm H20 (44 mm Hg)
  • Crack Pressure: 0- to -2 cm H20 (0 to -.8 in H20)
  • Exhalation Resistance: 0-10 LPM to 1.5 cm H20, 11-70 LPM to 3.8 H20
  • Gas Consumption Driving Gas: 0.5 LPM Max
  • Dead Space: 8 ml (excluding mask)
  • Supply Pressure: 40 to 90 psig
  • Operating Temperature: -30°F to 125°F
  • Storage Temperature: -40°F to 160°F
  • Inlet Fitting: Standard male oxygen DISS
  • Filter: 25 Micron Stainless Steel Mesh
  • Outlet: 22 mm outside diameter x 15 mm inside diameter (fits standard medical masks, endotracheal tubes and tracheostomy tubes)
  • Weight: 16 oz/450g
  • Body: Anodized aluminum
  • Cover: Polycarbonate
  • Outlet: Polysulfone
  • Inlet Fitting: Plated brass
Share by: